User Tools

Site Tools


drafts:dc_distribution

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
drafts:dc_distribution [2019-01-22 10:42] – external edit 127.0.0.1drafts:dc_distribution [2019-10-17 14:11] – [Lynx shunt] guy_stewart
Line 7: Line 7:
 It consists of the following modules: It consists of the following modules:
  
-  * Lynx Power In +  * [[https://www.victronenergy.com/dc-distribution-systems/lynx-power-in|Lynx Power In]] 
-  * Lynx Shunt +  * [[https://www.victronenergy.com/dc-distribution-systems/lynx-shunt-ve-can|Lynx Shunt]] 
-  * Lynx Distributor+  * [[https://www.victronenergy.com/dc-distribution-systems/lynx-distributor|Lynx Distributor]]
  
 You can use the Lynx Distributor or Lynx Power In without the Lynx Shunt. You can use the Lynx Distributor or Lynx Power In without the Lynx Shunt.
Line 31: Line 31:
  
 The Lynx shunt contains a positive bus-bar with space to mount a fuse and a negative bus-bar with a shunt. The Lynx shunt contains a positive bus-bar with space to mount a fuse and a negative bus-bar with a shunt.
-It also contains battery monitor electronics. The Lynx shunt can send via the VE.CAN bus battery motoring information to a CCGX or VGX or to a third party can bus monitoring system, such as a NMEA2000 (check with Johannes). The CCGX, VGX or third party display acts as battery monitor display and is also used to set up the built-in batter monitor. +It also contains battery monitoring electronics. The Lynx shunt can send via the VE.CAN bus battery monitoring information to a CCGX or VGX or to a third party CANbus monitoring system, such as a NMEA2000. The CCGX, VGX or third party display acts as battery monitor display and is also used to set up the built-in battery monitor.
- +
-The Lynx shunt is available in two models:  +
-  * VE.CAN +
-  * VE.NET (depreciated)+
  
 +The Lynx shunt is available with a VE.Can connection. A previous model had a VE.Net connection and is now discontinued.
 ==== Fuse ==== ==== Fuse ====
  
Line 95: Line 92:
  
 ==== Fuses ==== ==== Fuses ====
-Uses MEGA fuses. Please note that some MEGA fuses are only rated to 36Volt (suitable for 24V systems), You must use 64V rated fuses for 48V systems.+Uses MEGA fuses. Please note that some MEGA fuses are only rated to 36Volt (suitable for 24V systems), You must use 58/64V rated fuses for 48V systems.
 ==== Installation ==== ==== Installation ====
  
Line 134: Line 131:
  
 [[https://static1.squarespace.com/static/562bc73de4b0908330f67ee0/t/59d3f48fe9bfdf11a11df040/1507062949908/Redwood-+38RL-Victron.jpg|Closeup Photo of Lynx]] [[https://static1.squarespace.com/static/562bc73de4b0908330f67ee0/t/59d3f48fe9bfdf11a11df040/1507062949908/Redwood-+38RL-Victron.jpg|Closeup Photo of Lynx]]
- 
drafts/dc_distribution.txt · Last modified: 2019-10-18 13:14 by guy_stewart

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki