User Tools

Site Tools


ccgx:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
ccgx:start [2019-10-18 13:04]
guy_stewart [6.2 Compatible MFDs and instructions]
ccgx:start [2019-10-23 12:09] (current)
mvader [5.6 Remote Console on VRM - Trouble shooting]
Line 870: Line 870:
   - In VictronConnect,​ use the GX Log Converter feature to convert them to Excel sheets.   - In VictronConnect,​ use the GX Log Converter feature to convert them to Excel sheets.
  
-==== 5.6 Remote Console on VRM ====+==== 5.6 Remote Console on VRM - Setup ====
  
 This feature allows full remote control of a GX Device, over the internet: This feature allows full remote control of a GX Device, over the internet:
Line 884: Line 884:
 {{ :​vrm_portal:​vrm_remote_console.jpg?​direct }} {{ :​vrm_portal:​vrm_remote_console.jpg?​direct }}
  
-Trouble shooting ​tips:+==== 5.7 Remote Console on VRM - Trouble shooting ​====
  
-  ​- Make sure that basic communication with VRM works, see chapter 5.4. +Follow these steps to trouble shoot Remote Console on VRM 
-  - After enabling the feature, make sure to set (or disable) the password. + 
-  - Also make sure to restart the CCGX.+  ​- Make sure that Logging to the VRM portal ​works, see chapter 5.4. Without this; Remote Console on VRM will not work
 +  - After enabling the Remote Console ​feature, make sure to set (or disable) the password. 
 +  - Also make sure to restart the CCGX after setting (or disabling) the password.
   - Make sure to update the CCGX to the latest firmware version. The last stability improvement for Remote Console was made in version v2.30.   - Make sure to update the CCGX to the latest firmware version. The last stability improvement for Remote Console was made in version v2.30.
   - After the restart, check the Remote Console on VRM status shows online or a port number. In case it says offline, or port number 0, the CCGX was unable to connect to the Remote Console server. This is normally caused by a (company) firewall, blocking the connection. The solution is then to configure an exception rules in the firewall.   - After the restart, check the Remote Console on VRM status shows online or a port number. In case it says offline, or port number 0, the CCGX was unable to connect to the Remote Console server. This is normally caused by a (company) firewall, blocking the connection. The solution is then to configure an exception rules in the firewall.
ccgx/start.txt · Last modified: 2019-10-23 12:09 by mvader