ccgx:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
ccgx:start [2019-08-28 23:57] – [4.4 DVCC features for all systems] mvaderccgx:start [2019-10-01 11:28] – [2.1 Configurable parameters] guy_stewart
Line 178: Line 178:
 | SMA |  No  | LAN Connection, see [[ccgx:ccgx_sma|GX - SMA manual]] | | SMA |  No  | LAN Connection, see [[ccgx:ccgx_sma|GX - SMA manual]] |
 | SolarEdge |  No  | LAN Connection, see [[venus-os:gx_solaredge|GX - SolarEdge manual]] | | SolarEdge |  No  | LAN Connection, see [[venus-os:gx_solaredge|GX - SolarEdge manual]] |
-| ABB |  Yes  | LAN Connection, see [[https://www.victronenergy.com/live/ccgx:abb|GX ABB manual]] |+| ABB |  Yes  | LAN Connection, see [[https://www.victronenergy.com/live/ccgx:abb|GX ABB manual]] |
  
 === Using a meter === === Using a meter ===
Line 186: Line 186:
 ^ Type ^ Zero feed-in ^ Details ^ ^ Type ^ Zero feed-in ^ Details ^
 | [[https://www.victronenergy.com/accessories/ac-current-sensor|AC Current Sensor]] |  No  | Connected to inverter/charger analog input. Lowest cost - least accurate. [[ac_current_sensor:start|AC Current Sensor Manual]] | | [[https://www.victronenergy.com/accessories/ac-current-sensor|AC Current Sensor]] |  No  | Connected to inverter/charger analog input. Lowest cost - least accurate. [[ac_current_sensor:start|AC Current Sensor Manual]] |
-| [[https://www.victronenergy.com/accessories/energy-meter|Energy Meter]] |  No  | wired to the CCGX, or connected wirelessly using our Zigbee to USB/RS485 interfaces. The best solution. See the [[energy-meters:start]] | +| [[https://www.victronenergy.com/accessories/energy-meter|Energy Meter]] |  No  | wired to the CCGX, or connected wirelessly using our Zigbee to USB/RS485 interfaces. See the [[energy-meters:start]] | 
-| [[https://www.victronenergy.com/accessories/wireless-ac-sensor|Wireless AC sensors]] |  No  | See the [[ccgx:ccgx_wireless_ac_sensor]] |+| Wireless AC sensors |  No  | See the [[ccgx:ccgx_wireless_ac_sensor]] - Discontinued |
  
 ==== 1.6 Internet connectivity ==== ==== 1.6 Internet connectivity ====
Line 335: Line 335:
 |Enable password check | Choose password to allow remote console access.|| |Enable password check | Choose password to allow remote console access.||
 |Enable on VRM |No|Enabling on VRM will allow connection to the CCGX from anywhere via the VRM portal. [[vrm_portal:troubleshooting_ccgx_vrm_connectivity#trouble_shooting_remote_console_on_vrm|Trouble shooting Remote Console on VRM]]| |Enable on VRM |No|Enabling on VRM will allow connection to the CCGX from anywhere via the VRM portal. [[vrm_portal:troubleshooting_ccgx_vrm_connectivity#trouble_shooting_remote_console_on_vrm|Trouble shooting Remote Console on VRM]]|
-|Enable on LAN |No|Enabling will allow direct connection to the CCGX by typing it's IP address into a web browser. Only Enable this function on trusted networks.|+|Enable on LAN |No|Enabling will allow direct connection to the CCGX by typing it's IP address into a web browser. Only Enable this function on trusted networks. Disable password check, or set password first|
 |**System setup** ||| |**System setup** |||
 |AC input 1 |Generator |Select Generator or Grid. (We will shortly be adding the setting 'Shore power' instead of grid.) | |AC input 1 |Generator |Select Generator or Grid. (We will shortly be adding the setting 'Shore power' instead of grid.) |
Line 391: Line 391:
  
 {{:ccgx:menustructure_ccgx.jpeg?direct&200  }} {{:ccgx:menustructure_ccgx.jpeg?direct&200  }}
- 
 ==== 2.4 Battery State of Charge (SOC) ==== ==== 2.4 Battery State of Charge (SOC) ====
  
Line 928: Line 927:
  
   * [[https://docs.victronenergy.com/gx/mfd-garmin.html|Instructions for Garmin MFDs]]   * [[https://docs.victronenergy.com/gx/mfd-garmin.html|Instructions for Garmin MFDs]]
-  * [[venus-os:mfd-navico|Instructions for Navico MFDs]]+  * [[venus-os:mfd-navico|Instructions for Navico MFDs]] (Simrad, B&D, Lowrance)
  
 Raymarine: support on Raymarine MFDs is pending a Raymarine firmware update. [[https://www.victronenergy.com/blog/|Subscribe to our blog (link at the bottom)]], or for direct customers, monitor our weekly e-mail, to be informed about that release. Raymarine: support on Raymarine MFDs is pending a Raymarine firmware update. [[https://www.victronenergy.com/blog/|Subscribe to our blog (link at the bottom)]], or for direct customers, monitor our weekly e-mail, to be informed about that release.
ccgx/start.txt · Last modified: 2023-01-19 15:08 by 127.0.0.1