ccgx:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
ccgx:start [2019-03-08 12:25] – [Color Control GX manual] guy_stewart | ccgx:start [2019-05-21 11:08] – [1.6 Internet connectivity] mvader | ||
---|---|---|---|
Line 167: | Line 167: | ||
Alternatively, | Alternatively, | ||
- | ==== 1.5 Measuring | + | ==== 1.5 Monitoring |
Measuring the output of a PV Inverter will provide the user with an overview of both actual power balance and the energy distribution. Note that these measurements are only used to display information. They are not needed, nor used, by the installation for its performance. | Measuring the output of a PV Inverter will provide the user with an overview of both actual power balance and the energy distribution. Note that these measurements are only used to display information. They are not needed, nor used, by the installation for its performance. | ||
There are several ways to get the system to show the output of a PV Inverter: | There are several ways to get the system to show the output of a PV Inverter: | ||
- [[https:// | - [[https:// | ||
- | - [[http:// | + | - [[http:// |
- | - [[https:// | + | - [[https:// |
+ | - [[https:// | ||
- Using a [[https:// | - Using a [[https:// | ||
- By using [[https:// | - By using [[https:// | ||
Line 205: | Line 206: | ||
Using a Wi-Fi dongle it is possible to connect to WEP, WPA and WPA2 secured networks. There are four supported USB Wi-Fi dongles. Two of them are also available from stock at Victron Energy: | Using a Wi-Fi dongle it is possible to connect to WEP, WPA and WPA2 secured networks. There are four supported USB Wi-Fi dongles. Two of them are also available from stock at Victron Energy: | ||
- | * CCGX WiFi module simple (Nano USB), small, low cost. Victron part number BPP900100200 | + | * Partno. BPP900100200 - CCGX WiFi module simple (Nano USB), small, low cost. |
- | * [[https:// | + | * Partno. BPP900200300 - [[https:// |
- | * [[https:// | + | |
- | * [[https:// | + | |
- | New model coming early 2019: [[https:// | + | WiFi modules that are no longer available, but still supported, are: |
+ | * Partno. BPP900200100 - [[https:// | ||
+ | * Partno. BPP900100100 | ||
+ | * Partno. BPP900200200 - [[https:// | ||
Although other Wi-Fi dongles may work, they have not been tested and we do not offer support for other dongles. | Although other Wi-Fi dongles may work, they have not been tested and we do not offer support for other dongles. | ||
Line 601: | Line 603: | ||
Below features apply to all types of systems when DVCC is enabled: Offgrid, Backup, ESS, marine and others. And applies to all types of batteries: lead batteries as well as lithium batteries, both with and without a CAN-bus BMS connected to the Victron system. | Below features apply to all types of systems when DVCC is enabled: Offgrid, Backup, ESS, marine and others. And applies to all types of batteries: lead batteries as well as lithium batteries, both with and without a CAN-bus BMS connected to the Victron system. | ||
- | * A user-configurable maximum charge current setting. It works across the whole system. MPPTs are automatically prioritized over the mains/ | + | * A user-configurable maximum charge current setting. It works across the whole system. MPPTs are automatically prioritized over the mains/ |
* Shared voltage sense (SVS) for VE.Bus devices and VE.Direct Solar Chargers. | * Shared voltage sense (SVS) for VE.Bus devices and VE.Direct Solar Chargers. | ||
* The system automatically selects the best available voltage measurement. It will use the voltage from the BMS or a BMV battery monitor, if possible, otherwise it will use the battery voltage reported by the VE.Bus system. | * The system automatically selects the best available voltage measurement. It will use the voltage from the BMS or a BMV battery monitor, if possible, otherwise it will use the battery voltage reported by the VE.Bus system. | ||
* The voltage displayed on the GUI reflects the same voltage measurement. | * The voltage displayed on the GUI reflects the same voltage measurement. | ||
* Shared Voltage Sense (SVS) is by default enabled when DVCC is enabled. It can be disabled with a switch in the Settings -> System Setup menu. | * Shared Voltage Sense (SVS) is by default enabled when DVCC is enabled. It can be disabled with a switch in the Settings -> System Setup menu. | ||
- | |||
==== 3.3 Features for systems using a CAN-bus BMS systems ==== | ==== 3.3 Features for systems using a CAN-bus BMS systems ==== | ||
ccgx/start.txt · Last modified: 2023-01-19 15:08 by 127.0.0.1