ccgx:start [2019-03-08 12:25] – [Color Control GX manual] guy_stewartccgx:start [2019-03-26 08:35] mvader
Line 167: Line 167:
 Alternatively, instead of a VE.Can to NMEA200, you can use a 3802 cable from Oceanic Systems: https://osukl.com/ve-can-adaptor/. The difference is that it lends itself well to connecting a single NMEA-2000 device into a VE.Can network. It's also able to power a lower voltage NMEA-2000 network directly from a 48V Victron system. Alternatively, instead of a VE.Can to NMEA200, you can use a 3802 cable from Oceanic Systems: https://osukl.com/ve-can-adaptor/. The difference is that it lends itself well to connecting a single NMEA-2000 device into a VE.Can network. It's also able to power a lower voltage NMEA-2000 network directly from a 48V Victron system.
  
-==== 1.5 Measuring PV Inverter output ====+==== 1.5 Monitoring PV Inverter output ====
 Measuring the output of a PV Inverter will provide the user with an overview of both actual power balance and the energy distribution. Note that these measurements are only used to display information. They are not needed, nor used, by the installation for its performance. Measuring the output of a PV Inverter will provide the user with an overview of both actual power balance and the energy distribution. Note that these measurements are only used to display information. They are not needed, nor used, by the installation for its performance.
  
 There are several ways to get the system to show the output of a PV Inverter: There are several ways to get the system to show the output of a PV Inverter:
   - [[https://www.victronenergy.com/accessories/ac-current-sensor|An AC Current Sensor]], wired to the analog inputs of a Multi or Quattro provides the information at the lowest cost - though it is the least accurate. [[ac_current_sensor:start|AC Current Sensor Manual]].   - [[https://www.victronenergy.com/accessories/ac-current-sensor|An AC Current Sensor]], wired to the analog inputs of a Multi or Quattro provides the information at the lowest cost - though it is the least accurate. [[ac_current_sensor:start|AC Current Sensor Manual]].
-  - [[http://www.fronius.com/|Fronius PV Inverters]] can be read digitally via the local LAN. See the [[ccgx:ccgx_fronius|CCGX / Fronius manual]]. +  - [[http://www.fronius.com/|Fronius PV Inverters]] can be read digitally via the local LAN. See the [[ccgx:ccgx_fronius|GX - Fronius manual]]. 
-  - [[https://www.sma-australia.com.au/|SMA PV Inverters]] can be read digitally via the local LAN. See the [[ccgx:ccgx_sma|CCGX / SMA manual]].+  - [[https://www.sma.de/en/|SMA PV Inverters]] can be read digitally via the local LAN. See the [[ccgx:ccgx_sma|GX - SMA manual]]. 
 +  - [[https://www.solaredge.com/|SolarEdge PV Inverters]] can be read digitally via the local LAN. See the [[venus-os:gx_solaredge|GX - SolarEdge manual]].
   - Using a [[https://www.victronenergy.com/accessories/energy-meter|Victron Energy Meter]], either wired to the CCGX, or connected wirelessly using our Zigbee to USB/RS485 interfaces. See the [[energy-meters:start]].   - Using a [[https://www.victronenergy.com/accessories/energy-meter|Victron Energy Meter]], either wired to the CCGX, or connected wirelessly using our Zigbee to USB/RS485 interfaces. See the [[energy-meters:start]].
   - By using [[https://www.victronenergy.com/accessories/wireless-ac-sensor|Wireless AC sensors]]. See the [[ccgx:ccgx_wireless_ac_sensor]].   - By using [[https://www.victronenergy.com/accessories/wireless-ac-sensor|Wireless AC sensors]]. See the [[ccgx:ccgx_wireless_ac_sensor]].