-====== Generator auto start/stop on CCGX and Venus GX ======+====== GX - Generator auto start/stop ======
  
 ===== 1. Introduction ===== ===== 1. Introduction =====
Line 62: Line 62:
   * **Minimum run time**: It's good practice for a generator, once started, to be allowed to reach its operating temperature. When started manually this setting is ignored.   * **Minimum run time**: It's good practice for a generator, once started, to be allowed to reach its operating temperature. When started manually this setting is ignored.
  
-  * **Detect generator at AC input**: Enabling this feature will sound an alarm whenever power is //not// detected at the AC input terminal of the Inverter/Charger. This function will bring attention to a wide variety of problems; such as lack of fuel, or a mechanical or electrical fault at the generator. This functionality is not available for VE.Can connected Multi/Quattro.+  * **Detect generator at AC input**: Enabling this feature will raise an alarm on the GX device, as well as trigger an alarm email from the VRM portal(1), whenever power is //not// detected at the AC input terminal of the Inverter/Charger. This function will bring attention to a wide variety of problems; such as lack of fuel, or a mechanical or electrical fault at the generator. This functionality is not available for VE.Can connected Multi/Quattro. (1) requires automatic alarm monitoring on VRM to be enabled. Which it is by default.
  
   * **Quiet hours**: See [[#Quiet hours|Quiet hours]]   * **Quiet hours**: See [[#Quiet hours|Quiet hours]]