Line 1: Line 1:
-====== CCGX & Fischer Panda Gensets ======+====== GX - Fischer Panda generators ====== 
 + 
 +Fischer Panda generator can be connected to a GX Device, which makes it possible to monitor operate the generator as well as automatically start and stop it. 
 + 
 +The generator needs to be connected to the VE.Can port of the GX Device, which requires a Fischer Panda SAE J1939 module. 
 + 
 +===== Requirements ===== 
 +  * [[venus-os:start|GX Device]], with firmware v2.07 or later 
 +  * Fischer Panda generator, xControl or iGenerator 
 +  * Fischer Panda SAE J1939 CAN module (part number 0006107) 
 +  * Fischer Panda FP-Bus to VE.Can adapter (part number 0023441) 
 + 
 + 
 +Fischer Panda Firmware requirements: 
 +  * iControl (for the iGenerator): v2.17 minimum 
 +  * iControl panel: no minimum requirement 
 +  * xControl (for the constant speed generators): 4V38 minimum 
 +  * xContr panel: 4V29 
 +  * Fischer Panda SAE J1939 CAN module: 2V05 
 +  * Fischer Panda three phase module: 4V0b 
 +===== Connecting ===== 
 + 
 +==== xControl ==== 
 +The schematic below shows how to connect a Fischer Panda xControl generator. 
 +{{:ccgx:xcontrol_connection.png?650|}} 
 + 
 +==== iControl ==== 
 +The schematic below shows how to connect a Fischer Panda iControl generator. 
 +{{:ccgx:icontrol_connection.png?650|}} 
 + 
 +**:!: Important: Operation of the generator is only possible and allowed when the xControl or the iControl panel is switched on. ** 
 +===== GX Device ===== 
 + 
 +In Settings -> Services, the selected canbus profile must be one that says NMEA2000. (The default). 
 + 
 +When all wiring is complete and the setup has been correctly carried-out, the Fischer Panda will show up in the device list: 
 + 
 +{{:ccgx:fischerpanda-devicelist_29648454.png?400|}} 
 + 
 +Entering the Fischer Panda device on the menu reveals a page like this: 
 + 
 +{{:ccgx:fischerpanda-menu_29648486.png?400|}} 
 + 
 +Notice that it features an on/off switch as well as displaying status information, and the main AC parameters: voltage, current and power.  
 + 
 +Engine temperature, RPM and additional information are all available by entering the //Engine// sub menu item. 
 + 
 +{{:ccgx:fischerpanda-enginemenu.png?400|}} 
 +===== Generator start/stop ===== 
 +In addition to the manual start/stop and monitoring, there is also an automatic start/stop feature. This has the same comprehensive range of options as the Generator start/stop feature associated with the GX relay. 
 +See [[ccgx:generator_start_stop]] for the manual. 
 + 
 +{{:ccgx:fischerpanda-generatoroverview.png?400|}} 
 + 
 +===== Maintenance ===== 
 +Whenever performing maintenance on the generator, be sure to //stop// the generator from the Fischer Panda control panel. This will disable the Fischer Panda autostart feature, and ensures that the generator cannot be remotely started - by a CCGX, for example.  
 + 
 +When the maintenance is completed, make sure you enable the autostart feature again. You can do this on the Fischer Panda control panel in the menu ''generator -> autostart -> turn on / off''
 + 
 +===== MFD App ==== 
 + 
 +The Marine MFD HTML5 app (more information [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_app|here]]) also contains an element which allows monitoring as well as control of the Fischer Panda generator: 
 + 
 +{{ :ccgx:fischer_panda_control.png?nolink |}} 
 +===== Troubleshooting ===== 
 + 
 +=== I've set the mode of the genset to 'On' or 'Auto start/stop' but the generator is not starting/running. === 
 +Make sure the Fischer Panda autostart feature is on, this allows the GX control the remote on/off of the genset. You can find this option on the control panel in the menu ''generator -> autostart -> turn on / off''
 + 
 +If you're manually trying to start the genset, a toast message appears with the text ''AutoStart functionality is currently disabled, enable it on the genset panel in order to start the genset from this menu''
 +{{:ccgx:fischerpanda-fpautostart_disabled2.png?400|}} 
 + 
 +If the generator auto start/stop is enabled, it will show error ''#1 Remote switch control disabled'' on the Auto start/stop page. 
 +{{:ccgx:fischerpanda-fpautostart_disabled.png?400|}} 
 + 
  
  