User Tools

Site Tools


ccgx:ccgx_fronius

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
ccgx:ccgx_fronius [2019-01-22 10:16] – external edit 127.0.0.1ccgx:ccgx_fronius [2019-09-18 07:52] – [2.2 Adding Fronius to the CCGX] mvader
Line 1: Line 1:
 ====== CCGX & Fronius PV Inverters ====== ====== CCGX & Fronius PV Inverters ======
  
-By connecting a Fronius PV Inverter and [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] (CCGX) together you be able to:+By connecting a Fronius PV Inverter and [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] (CCGX) together you will be able to:
   - See Fronius information on the CCGX.   - See Fronius information on the CCGX.
   - Monitor the Fronius on the VRM Portal.   - Monitor the Fronius on the VRM Portal.
Line 80: Line 80:
 4. Configure the //position// relative to the Multi or Quattro (is it: AC Input / AC Output); and the //phase// for each inverter in the list: \\ {{:ccgx:ccgx-fronius-position.png?nolink|}} \\ \\ 4. Configure the //position// relative to the Multi or Quattro (is it: AC Input / AC Output); and the //phase// for each inverter in the list: \\ {{:ccgx:ccgx-fronius-position.png?nolink|}} \\ \\
     * Position: = the position relative to the Multi or Quattro [AC Input 1 / AC Input 2 / AC Output]     * Position: = the position relative to the Multi or Quattro [AC Input 1 / AC Input 2 / AC Output]
-    * Phase: = the phase on which the PV Inverter installed. Disabled and set to Multi-phase for split- and three-phase PV Inverters  +    * Phase: = the phase on which the PV Inverter installed. This setting is automatically set to Multi-phase for split- and three-phase PV Inverters  
     * Show: = show this device in the system or not. Use this feature when there are multiple, separate, energy systems on the same LAN.     * Show: = show this device in the system or not. Use this feature when there are multiple, separate, energy systems on the same LAN.
  
Line 108: Line 108:
  
 {{ :ccgx:ccgx-fronius-device2.png?nolink |}} {{ :ccgx:ccgx-fronius-device2.png?nolink |}}
 +
 +=== Inverter status ===
 +
 +The following status values are supported:
 +^ State ^ Meaning ^
 +| Standby | The PV-inverter is not generating power. |
 +| Startup | The PV-inverter is starting up, but not generating power yet. |
 +| Running (MPPT) | The PV-inverter is running at maximum power. |
 +| Running (Throttled) | The PV-inverter is running, but power is being throttled. |
 +| Error | One or more errors are present.\\ Note that not all errors will cause the PV-inverter to shut down. |
  