 ====== CCGX & Fronius PV Inverters ====== ====== CCGX & Fronius PV Inverters ======
  
-By connecting a Fronius PV Inverter and [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] (CCGX) together you be able to:+By connecting a Fronius PV Inverter and [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] (CCGX) together you will be able to:
   - See Fronius information on the CCGX.   - See Fronius information on the CCGX.
   - Monitor the Fronius on the VRM Portal.   - Monitor the Fronius on the VRM Portal.
Line 13: Line 13:
 | Fronius Symo       | No accessory needed, datamanager card installed from factory | | Fronius Symo       | No accessory needed, datamanager card installed from factory |
 | Fronius Galvo      | No accessory needed, datamanager card installed from factory | | Fronius Galvo      | No accessory needed, datamanager card installed from factory |
 +| Fronius Primo      | No accessory needed, datamanager card installed from factory |
 | Fronius IG Plus (*)   | Purchase and install the [[http://www.fronius.com/cps/rde/xchg/SID-FD8CF128-0D078554/fronius_international/hs.xsl/83_27954_ENG_HTML.htm#.VPhTUfnF_jU|datamanager 2.0]] | | Fronius IG Plus (*)   | Purchase and install the [[http://www.fronius.com/cps/rde/xchg/SID-FD8CF128-0D078554/fronius_international/hs.xsl/83_27954_ENG_HTML.htm#.VPhTUfnF_jU|datamanager 2.0]] |
 | Fronius Agilo      | Purchase and install the [[http://www.fronius.com/cps/rde/xchg/SID-FD8CF128-0D078554/fronius_international/hs.xsl/83_27954_ENG_HTML.htm#.VPhTUfnF_jU|datamanager box]] | | Fronius Agilo      | Purchase and install the [[http://www.fronius.com/cps/rde/xchg/SID-FD8CF128-0D078554/fronius_international/hs.xsl/83_27954_ENG_HTML.htm#.VPhTUfnF_jU|datamanager box]] |
Line 26: Line 27:
 ===== 2. Configuring ===== ===== 2. Configuring =====
  
-==== 2.1 Setup ====+==== 2.1 Setup Local Area Network (LAN) Configuration==== 
 +In order to establish a data communication between the Fronius and the CCGX, you will have to setup a valid LAN IP address on the Fronius, using one of the following methods. If you are in doubt, which method is the best for your network, please ask your system administrator or IT support.
  
-  - Connect both the Fronius and the CCGX on the same LAN network, in the same subnet. (If you don't know what a subnet is, don't worry you'll probably be fine!) +=== 2.1.1 DHCP addressing method === 
-  Configure the Fronius datamanager using its manual(On DHCP networksno configuration of the datamanager is required.+If you have a DHCP server running on the LAN the Fronius and CCGX are connected to, you don't need to manually configure your LAN IP addresses as the DHCP server does this for you. Make sure, that the "IP Switch" is in "B" (default) position on the datamanager, to allow the Fronius to obtain it's IP address. It can be reviewed in the Address Lease Table of the DHCP server. 
-  - In the CCGX, navigate to //Settings// and then the //Fronius PV Inverters// section. You will see this menu: \\ {{:ccgx:fronius_setup_menu.png?nolink|}} \\ \\ + 
-  Select //Scan// in the CCGX menu, and after completion go into the Inverters submenu to see the results. If scanning does not find the inverter, manually add the IP address of the Fronius Datamanager from its card, or box. +=== 2.1.2 Link-local addressing method  === 
-  Once located, you will see the Inverters listed in the menu. The name used will be the serial number of the inverter - which you will also find on the inverter itself: \\ {{:ccgx:ccgx-fronius-inverters.png?nolink|}} \\ \\ +When no DHCP server is present on the LAN and you only have one Fronius unit to connect, Link-local addressing can be used to establish data communication between the CCGX and the Fronius. 
-  Configure the //position// relative to the Multi or Quattro (is it: AC Input / AC Output); and the //phase// for each inverter in the list: \\ {{:ccgx:ccgx-fronius-position.png?nolink|}} \\ \\+This could be the case, if you use a WiFi Network for the CCGX to gain access to the Internet and have a Fronius connected to the wired LAN Interface of that CCGX.  
 + 
 +Note, that no direct access to the internet will be possible for the Fronius in that configuration and therefore only communication to the CCGX is possible.  
 + 
 +This method can only be used to configure a single Fronius unit within a LAN. Multiple Fronius devices in the same LAN must be configured with DHCP, or manual addressing method. 
 +  - Make sure the "IP Switch" on the Fronius Datamanager is on position "A" {{:ccgx:fronius_datamanager_ip_switch.png?600|}} 
 +  - Connect boththe Fronius and the CCGXon the same LAN network, either directly with a LAN cable or using a network switch.  
 +  - The Fronius is now accessible and having a "Link-local" capable IP address configured: 169.254.0.180 
 + 
 +=== 2.1.3 manual addressing method === 
 +You will have to configure the IP address of the Fronius to be in the same subnet as the IP address of the CCGXTo do this, first have a look at the IP configuration your CCGX is using on that network.  
 + 
 +The IP configuration can be reviewed in Settings --> Ethernet. The important settings are the IP address and Subnet Mask. 
 + 
 +If the LAN IP address and Subnet Mask of the CCGX is not configured yet, you will have to set it first.  
 + 
 +As an example, the IP address on the CCGX could be: 192.168.10.1 and the Subnet Mask: 255.255.255.0.  
 + 
 +Configuring the Fronius to the same subnet means setting manual IP address to: 192.168.10.2 and the same Subnet Mask of 255.255.255.0 on the Fronius.  
 + 
 +Every device on your LAN has to have a unique (different) IP address and so the last segment (.1/.2) in this example has to differ on every device on the same LAN. The highest value, that can be set for this segment is 254.  
 + 
 +The subnet is described by the first 3 segments in this case and so they have to be the same. Configuring multiple devices with exactly the same IP addresses will lead to network errors. Use different IP subnets for the WiFi and wired LAN interface. The IP address ranges used on each interface should differ in the third segment. 
 + 
 +As an example: 192.168.10.1-254 for LAN IP's and 192.168.11.1-254 for WiFi IP's. 
 + 
 +Configure the Fronius Datamanager to use an IP address on the same subnet, as described above 
 +You may need to refer to the Fronius operating manual for how this is done for your Fronius Inverter model  
 + 
 +If you would like to connect the Fronius to be able to use the internet connection of your Local network, you have to set Gateway and DNS IP addresses on the Fronius as wellThey should be exactly the same as in the Settings --> Ethernet of the CCGX. 
 + 
 + 
 + 
 + 
 + 
 +==== 2.2 Adding Fronius to the CCGX ==== 
 + 
 +1. In the CCGX, navigate to //Settings// and then the //Fronius PV Inverters// section. You will see this menu: \\ {{:ccgx:fronius_setup_menu.png?nolink|}} \\ \\ 
 + 
 +2. Select //Scan// in the CCGX menu, and after completion go into the Inverters submenu to see the results. If scanning does not find the inverter, manually add the IP address of the Fronius Datamanager <del>from its card, or box.</del> 
 + 
 +3. Once located, you will see the Inverters listed in the menu. The name used will be the serial number of the inverter - which you will also find on the inverter itself: \\ {{:ccgx:ccgx-fronius-inverters.png?nolink|}} \\ \\ 
 + 
 +4. Configure the //position// relative to the Multi or Quattro (is it: AC Input / AC Output); and the //phase// for each inverter in the list: \\ {{:ccgx:ccgx-fronius-position.png?nolink|}} \\ \\
     * Position: = the position relative to the Multi or Quattro [AC Input 1 / AC Input 2 / AC Output]     * Position: = the position relative to the Multi or Quattro [AC Input 1 / AC Input 2 / AC Output]
-    * Phase: = the phase on which the PV Inverter installed. Disabled and set to Multi-phase for split- and three-phase PV Inverters  +    * Phase: = the phase on which the PV Inverter installed. This setting is automatically set to Multi-phase for split- and three-phase PV Inverters  
     * Show: = show this device in the system or not. Use this feature when there are multiple, separate, energy systems on the same LAN.     * Show: = show this device in the system or not. Use this feature when there are multiple, separate, energy systems on the same LAN.
-  - Done! 
  
-==== 2.Device scan details ====+5. Done! 
 +==== 2.Device scan details ====
 As mentioned above the CCGX should find all Fronius inverters automatically. It will scan all IP-addresses in the local network (that is, all IP-addresses within the netmask assigned to the CCGX) to check whether or not they are //Fronius datamanager// cards. This scan will be performed during CCGX startup; whenever the CCGX loses connection to a data card; and a scan can also be initiated manually by selecting 'Press to scan'. As mentioned above the CCGX should find all Fronius inverters automatically. It will scan all IP-addresses in the local network (that is, all IP-addresses within the netmask assigned to the CCGX) to check whether or not they are //Fronius datamanager// cards. This scan will be performed during CCGX startup; whenever the CCGX loses connection to a data card; and a scan can also be initiated manually by selecting 'Press to scan'.
  
Line 48: Line 93:
 If you changed to //TCP// port number on the data manager, you should change this setting on the CCGX, too (TCP port) - otherwise leave the setting at its default (80). If you changed to //TCP// port number on the data manager, you should change this setting on the CCGX, too (TCP port) - otherwise leave the setting at its default (80).
  
-==== 3. Monitoring CCGX ====+===== 3. Monitoring CCGX ====
 When the Fronius is detected and configured on the CCGX all PV inverters will be visible in the devicelist. When the Fronius is detected and configured on the CCGX all PV inverters will be visible in the devicelist.
  
Line 63: Line 109:
 {{ :ccgx:ccgx-fronius-device2.png?nolink |}} {{ :ccgx:ccgx-fronius-device2.png?nolink |}}
  
 +=== Inverter status ===
 +
 +The following status values are supported:
 +^ State ^ Meaning ^
 +| Standby | The PV-inverter is not generating power. |
 +| Startup | The PV-inverter is starting up, but not generating power yet. |
 +| Running (MPPT) | The PV-inverter is running at maximum power. |
 +| Running (Throttled) | The PV-inverter is running, but power is being throttled. |
 +| Error | One or more errors are present.\\ Note that not all errors will cause the PV-inverter to shut down. |
 +
 +===== 4. Monitoring on the VRM Portal =====
  
-==== 4. Monitoring on the VRM Portal ==== 
 To see the yield on the VRM site (in the //Advanced// tab), don't forget to enable the PV Inverter yield widget(s) in Settings -> Advanced tab setup. To see the yield on the VRM site (in the //Advanced// tab), don't forget to enable the PV Inverter yield widget(s) in Settings -> Advanced tab setup.
  
Line 71: Line 127:
 ===== DISQUS ===== ===== DISQUS =====
 ~~DISQUS~~ ~~DISQUS~~
 +