ccgx:ccgx_faq
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | Next revisionBoth sides next revision | ||
ccgx:ccgx_faq [2019-06-06 15:54] – [Q24: What is Error #42?] mvader | ccgx:ccgx_faq [2019-06-14 07:35] – [Q20: Issues with Multi not starting when CCGX is connected / Caution when powering the CCGX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro] guy_stewart | ||
---|---|---|---|
Line 157: | Line 157: | ||
==== Q20: Issues with Multi not starting when CCGX is connected / Caution when powering the CCGX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro ==== | ==== Q20: Issues with Multi not starting when CCGX is connected / Caution when powering the CCGX from the AC-out terminal of a VE.Bus Inverter, Multi or Quattro ==== | ||
- | If you power the CCGX from an AC adaptor connected to the AC-out port of any VE.Bus product (Inverter, Multi or Quattro), then a deadlock will occur after the VE.Bus products are powered-down for any reason (after any operational fault or during a black start). The VE.Bus devices will not boot-up until the CCGX has power ...but the CCGX will not boot-up until //it// has power. See FAQ for more information about this. | ||
- | This deadlock can be rectified by briefly unplugging the CCGX VE.Bus cable at which point you will observe the VE.Bus products will immediately begin to boot-up. | + | Make sure that the GX device and MultiPlus is running |
- | + | ||
- | This deadlock can be avoided in two ways: | + | |
- | * Power the CCGX from the battery; or | + | |
- | * Cut pin 7 in the VE.Bus cable connected to the CCGX | + | |
- | + | ||
- | Cutting/ | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | The // | + | |
==== Q21: I love Linux, programming, | ==== Q21: I love Linux, programming, | ||
ccgx/ccgx_faq.txt · Last modified: 2021-02-05 11:34 by marmour