User Tools

Site Tools


ccgx:ccgx_faq

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
ccgx:ccgx_faq [2019-01-21 10:58] – [DISQUS] ictbeheerccgx:ccgx_faq [2019-05-17 16:18] – [Q1: I cannot switch my Multi/Quattro system on or off] john_r
Line 5: Line 5:
  
 === Step by step instructions when connected to VE.Bus port on the CCGX === === Step by step instructions when connected to VE.Bus port on the CCGX ===
-  - Update the Color Control to the latest available version. See our blog posts in the [[https://www.victronenergy.com/blog/category/firmware/|firmware category]].+  - Update the Color Control to the latest available version. See our blog posts in the [[https://www.victronenergy.com/blog/category/firmware-software/]].
   - Do you have a Digital Multi Control or VE.Bus BMS in the system? In that case it is normal that on/off is disabled. See also the VE.Bus related notes in the [[:ccgx:start#connecting_victron_products|CCGX manual]]   - Do you have a Digital Multi Control or VE.Bus BMS in the system? In that case it is normal that on/off is disabled. See also the VE.Bus related notes in the [[:ccgx:start#connecting_victron_products|CCGX manual]]
   - In case you have had a Digital Multi Control or VE.Bus BMS connected to your system, the Color Control remembers it and even when those accessories have been removed the On/off switch will still be disabled. To clear the memory, execute a Redetect system, the option is in the Multi or Quattro section of the Color Control GX menu.   - In case you have had a Digital Multi Control or VE.Bus BMS connected to your system, the Color Control remembers it and even when those accessories have been removed the On/off switch will still be disabled. To clear the memory, execute a Redetect system, the option is in the Multi or Quattro section of the Color Control GX menu.
Line 15: Line 15:
   - Do you have a Digital Multi Control or VE.Bus BMS in the system? In that case it is normal that on/off is disabled. See also the VE.Bus related notes in the [[:ccgx:start#connecting_victron_products|CCGX manual]]   - Do you have a Digital Multi Control or VE.Bus BMS in the system? In that case it is normal that on/off is disabled. See also the VE.Bus related notes in the [[:ccgx:start#connecting_victron_products|CCGX manual]]
   - In case you have had a Digital Multi Control or VE.Bus BMS connected to your system, and it is now no longer connected, the Canbus interface remembers it. Therefore, even after those accessories have been removed, the On/off switch will still be disabled. Clearing this memory is unfortunately not possible yourself, please contact us so we can help you.   - In case you have had a Digital Multi Control or VE.Bus BMS connected to your system, and it is now no longer connected, the Canbus interface remembers it. Therefore, even after those accessories have been removed, the On/off switch will still be disabled. Clearing this memory is unfortunately not possible yourself, please contact us so we can help you.
- 
 ==== Q2: Do I need a BMV to see proper battery state of charge? ===== ==== Q2: Do I need a BMV to see proper battery state of charge? =====
  
Line 117: Line 116:
  
 Two way communication (Remote VEConfig and Remote Firmware updates): Two way communication (Remote VEConfig and Remote Firmware updates):
-   * Uses HTTPS (port 443) to the Pubnub servers+   Pre-v2.20: Uses HTTPS (port 443) to the Pubnub servers 
 +   * v2.20 and later: connects to mqtt-rpc.victronenergy.com on port 443
  
 MQTT (default disabled): MQTT (default disabled):
-   * When enabled, a MQTT broker is started, which accepts TCP connections on port 1883. The CCGX will also try to connect to the victron MQTT cloud server (mqtt.victronenergy.com) using SSL on port 8883.+   * When enabled, a local MQTT broker is started, which accepts TCP connections on port 1883. The CCGX will also try to connect to the victron MQTT cloud server (mqtt.victronenergy.com) using SSL on port 8883.
  
 Remote Console on VRM (default disabled): Remote Console on VRM (default disabled):
Line 188: Line 188:
 The software included in this product contains copyrighted software that is licensed under the GPL. You may obtain the Corresponding Source code from us for a period of three years after our last shipment of this product. The software included in this product contains copyrighted software that is licensed under the GPL. You may obtain the Corresponding Source code from us for a period of three years after our last shipment of this product.
  
 +
 +===== DISQUS =====
 +~~DISQUS~~
  
ccgx/ccgx_faq.txt · Last modified: 2021-02-05 11:34 by marmour

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki