Previous revision
ccgx:beta-testing [2018-12-06 07:13] mvaderccgx:beta-testing [2023-07-05 07:30] (current) – [How to join the program?] mvader
Line 3: Line 3:
 Would you like to become a Beta tester? Would you like to become a Beta tester?
  
-Venus OS - or //Venus// for short - is the operating software for our //Color Control GX// and //Venus GX//. Extensive field testing over a wide variety of installation-types and user-cases is very valuable to us ...and we're very grateful to you for your interest in joining this program, and for your help.+Venus OS - or //Venus// for short - is the operating software for our range of GX monitoring products, such as the Cerbo GX. Extensive field testing over a wide variety of installation-types and user-cases is very valuable to us ...and we're very grateful to you for your interest in joining this program, and for your help.
  
 ==== What happens when I join the program? ==== ==== What happens when I join the program? ====
Line 15: Line 15:
 This is a note to dealers & installers: **Do not install test versions on a customer's installation**. This is a note to dealers & installers: **Do not install test versions on a customer's installation**.
  
-These versions are called //test versions//, or //release-candidates// for a reason, and must not imposed on customers who naturally expect their system to be stable.+These versions are called //beta versions//, //test versions//, or //release-candidates// for a reason, and must not imposed on customers who expect and need their system to be stable.
  
-==== Where should I post possible issues? ====+Also, don't contact Victron dealers, installers, support, or sales managers or anyone else in case you see problems while running a beta version. The only channel for issues in such case is the relevant open Venus OS post on the Modifications section on Community. 
 +==== Where should I post possible bug reports? ====
 If you think you have found a bug, first of all install the latest official release again (a version without the ~ notation) to check that if that solves it. Sometimes you can go back by using the Backup firmware option. If that also contains a beta version, then you’ll need to install the official version by hand. Download the .swu file from https://professional.victronenergy.com and then follow the manual install procedure; using a usb stick or as card. If you think you have found a bug, first of all install the latest official release again (a version without the ~ notation) to check that if that solves it. Sometimes you can go back by using the Backup firmware option. If that also contains a beta version, then you’ll need to install the official version by hand. Download the .swu file from https://professional.victronenergy.com and then follow the manual install procedure; using a usb stick or as card.
  
 If the problem also exists with the official release; then contact normal support. If the problem also exists with the official release; then contact normal support.
  
-If the problem only exists in the beta version, then please reply to the emails containing the change logs; or send them to the [[https://groups.google.com/forum/#!forum/victron-dev-venus|dev-venus mailing list]]. Do not raise issues on //Disqus// pages, Comminity forum - or any of the regular support channels for bugs in beta versions.+If the problem only exists in the beta version, then please post a message on the relevant Venus OS beta version thread on [[https://community.victronenergy.com/spaces/31/index.html|the Modifications space on Community]]. Usually its pinned to the top there. Do not raise issues on //Disqus// pages, normal Community forum - nor any of the other regular support channels for bugs in beta versions.
  
 And don't forget to mention which test version you are using. And don't forget to mention which test version you are using.
Line 28: Line 29:
 ==== How to join the program? ==== ==== How to join the program? ====
 Go to Settings -> Firmware -> Online updates -> Update to, and there select //Latest release candidate//. Go to Settings -> Firmware -> Online updates -> Update to, and there select //Latest release candidate//.
- 
-To receive the emails about the test versions, make sure you register the device on the VRM Portal, and change the setting so that you have admin rights on the product. 
- 
 ==== How can I install the latest beta firmware? ==== ==== How can I install the latest beta firmware? ====
  
Line 37: Line 35:
 ...or alternatively, to install the version with a usb-stick or sd card, download the latest image here: ...or alternatively, to install the version with a usb-stick or sd card, download the latest image here:
  
-http://updates.victronenergy.com/feeds/venus/candidate/images+https://updates.victronenergy.com/feeds/venus/candidate/images
  
-You will find the Venus GX images in the directory titled//beaglebone///.+Which directory to use depends on the GX Device you have:
  
 +  * Venus GX: beaglebone
 +  * Cerbo GX: einstein
 +  * MultiPlus-II GX, or EasySolar-II GX: nanopi
  
-==== How do I know if the firmware I am running is a beta version? ==== 
-Beta versions are marked with a tilde (~) followed by the test version number. For example, v2.06~12 is test version number 12 of version v2.06. When releasing the final version of v2.06, the tilde and test number are removed, and the firmware is simply released as v2.06. 
  
-==== Where can find the change logs? ==== +==== How do know if the firmware I am running is a offical release? ====
-Change logs of the official releases are on [[https://professional.victronenergy.com/|Victron Professional]].+
  
-Change logs of the test versions are emailed to the test groupThey can also be found on the [[https://groups.google.com/forum/#!forum/victron-dev-venus|developers mailing list]].+Official releases have a clean version number, ie v2.06, or v2.10.
  
 +Version with a tilde in their version number, are either internal test versions, or beta versions.
 +
 +For example, v2.06~12 is test version number 12 of version v2.06. The next build will be v2.06~13, and so forth. When releasing the final version of v2.06, the tilde and test number are removed, and the firmware is officially released as v2.06.
 +
 +==== Where can I find the change logs? ====
 +Change logs for beta versions are on the [[https://community.victronenergy.com/spaces/31/index.html|Modifications section on Community]], as pinned posts to the top of that page.
 +
 +Change logs of the official releases are on [[https://professional.victronenergy.com/|Victron Professional]].
 ==== I have a problem, how can I return to the previous version? ==== ==== I have a problem, how can I return to the previous version? ====
 You can always return to the previously installed version: You can always return to the previously installed version:
Line 59: Line 65:
  
 ==== How can I unsubscribe to the emails? ==== ==== How can I unsubscribe to the emails? ====
-By un-joining the program: Go to Settings -> Firmware -> Online updates -> Update to, and there select //Latest release//As long as you are using //release-candidates// or //beta// versions of our software, it will not be possible to unsubscribe. Not even by using the unsubscribe link at the bottom of the email.+ 
 +Only be changing the parameter in the Victron equipment (ie. GX Device) that configures it to use beta software. See next chapter. 
 + 
 + 
 +==== How can I leave the beta testing program? ==== 
 + 
 +On your GX Device, go to Settings -> Firmware -> Online updates -> Update to
 + 
 +There, select //Latest release//. 
 + 
 +The other option, //Release-candidate// is the setting that enables the beta testing participation. 
  