Line 56: | Line 56: | ||
==== Common issues we have seen from other DIY / Self-build oriented BMSes ==== | ==== Common issues we have seen from other DIY / Self-build oriented BMSes ==== | ||
- | Batteries | + | Batteries |
- | + | ||
- | In this case the Victron | + | |
- | + | ||
- | Another common example is Victron requires the BMS to change the Charge Voltage Limit to restrict power flowing to the battery as it gets full. If the BMS attempts restriction using the Charge Current Limit without adjusting the Charge Voltage Limit it can cause Overcharge, Overvoltage or Overcurrent warnings. | + | |
+ | For example the Victron inverter/ | ||
+ | Another common problem as a battery becomes fully charged, Victron requires the BMS to change the Charge Voltage Limit (CVL) to restrict the power flowing to the battery. If, however, the BMS attempts to restrict power using the Charge Current Limit, without adjusting the Charge Voltage Limit, this can trigger Overcharge, Overvoltage or Overcurrent warnings. | ||