| battery_compatibility:sss [2026-03-10 07:57] – created guy_stewart | battery_compatibility:sss [2026-03-16 12:59] (current) – [2. Victron Device Compatibility] guy_stewart | ||
|---|---|---|---|
| Line 15: | Line 15: | ||
| ==== 1.1 ES Range (Residential) ==== | ==== 1.1 ES Range (Residential) ==== | ||
| - | ^ Model ^ Total Energy (kWh) ^ Usable Energy @ 80% DOD (kWh) ^ Nominal Voltage ^ Nominal Capacity ^ Max Charge (A) ^ Max Discharge (A) ^ Rec. Inverter ^ | + | ^ Model ^ Total Energy (kWh) ^ Usable Energy @ 80% DOD (kWh) ^ Nominal Voltage ^ Nominal Capacity ^ Max Charge (A) ^ Max Discharge (A) ^ Rec. Inverter |
| | ES5.4K | | ES5.4K | ||
| - | | ES7.4K | + | | ES7.4K |
| - | | ES9.4K | + | | ES9.4K |
| - | | ES12K | 12.0 | 9.6 | 51.2V | — | 160 | 200 | — | | + | | ES12K | 12.0 | 9.6 | 51.2V | — | 160 | 200 | 10 kVA | |
| | ES18K | 18.0 | 14.4 | 51.2V | 352 Ah | 320 | 400 | 15 kVA | | | ES18K | 18.0 | 14.4 | 51.2V | 352 Ah | 320 | 400 | 15 kVA | | ||
| - | | ES24K | 24.0 | 19.2 | 51.2V | — | 320 | 400 | — | + | | ES24K | 24.0 | 19.2 | 51.2V | — | 320 | 400 | 15 kVA | |
| - | Nominal voltage for all ES Range models is **51.2V** (16 cells × 3.2V per cell). " | + | Nominal voltage for all ES Range models is **51.2V** (16 cells × 3.2V per cell). " |
| Line 44: | Line 44: | ||
| * **GX Devices:** Cerbo GX, Cerbo-S GX, Ekrano GX | * **GX Devices:** Cerbo GX, Cerbo-S GX, Ekrano GX | ||
| - | * **Inverter/ | + | * **Inverter/ |
| + | * EasySolar GX, MultiPlus-II GX - note these GX inverters include an integrated GX device and do not require an additional seperate GX device | ||
| * **Solar Chargers:** SmartSolar MPPT (minimum firmware: see Section 3) | * **Solar Chargers:** SmartSolar MPPT (minimum firmware: see Section 3) | ||
| * **Monitoring: | * **Monitoring: | ||
| Line 267: | Line 268: | ||
| * If the keepalive message is not received **and** the minimum cell voltage drops to or below **2,800 mV**, the hardware breaker will trip to protect the battery cells | * If the keepalive message is not received **and** the minimum cell voltage drops to or below **2,800 mV**, the hardware breaker will trip to protect the battery cells | ||
| - | ==== 11.2 Black Start Test Results ==== | ||
| - | |||
| - | Black start testing was conducted in accordance with the four official testing protocols provided by Victron R&D. The StorageDOCK ES5.4K passed all required tests. | ||
| - | |||
| - | === Black Start from PV Input === | ||
| - | |||
| - | ESS Mode during test: **Keep batteries charged** | Grid feed-in DC-coupled PV: **OFF** | ||
| - | |||
| - | ^ Parameter ^ Value ^ | ||
| - | | PV Input at Test Start | 120V @ 8A | | ||
| - | | Battery SOC at Start | 0% (full BMS shutdown had occurred) | | ||
| - | | SOC at Inverter Boot | 6% | | ||
| - | | SOC When Next Test Commenced | 11% | | ||
| - | |||
| - | **VRM telemetry – at 0% SOC (pre-recovery): | ||
| - | |||
| - | ^ Measurement ^ Value ^ | ||
| - | | Battery Voltage | ||
| - | | Min Cell Voltage | 2.62V | | ||
| - | | Max Cell Voltage | 3.09V | | ||
| - | |||
| - | **VRM telemetry – at 11% SOC (post-recovery): | ||
| - | |||
| - | ^ Measurement ^ Value ^ | ||
| - | | Battery Voltage | ||
| - | | Min Cell Voltage | 3.21V | | ||
| - | | Max Cell Voltage | 3.25V | | ||
| - | |||
| - | === Black Start from AC Input === | ||
| - | |||
| - | ^ Parameter ^ Value ^ | ||
| - | | Starting SOC | 11% | | ||
| - | | SOC at BMS Shutdown | 5% | | ||
| - | | SOC at Inverter Boot (after AC connected) | 6% | | ||
| - | | Final SOC Achieved | 99% | | ||
| - | |||
| - | **VRM telemetry – at 5% SOC (pre-recovery): | ||
| - | |||
| - | ^ Measurement ^ Value ^ | ||
| - | | Battery Voltage | ||
| - | | Min Cell Voltage | 2.55V | | ||
| - | | Max Cell Voltage | 3.07V | | ||
| - | |||
| - | **VRM telemetry – at 99% SOC:** | ||
| - | |||
| - | ^ Measurement ^ Value ^ | ||
| - | | Battery Voltage | ||
| - | | Min Cell Voltage | 3.38V | | ||
| - | | Max Cell Voltage | 3.40V | | ||
| - | |||
| - | **VRM telemetry – at 100% SOC (30 minutes after reaching 99%):** | ||
| - | |||
| - | ^ Measurement ^ Value ^ | ||
| - | | Battery Voltage | ||
| - | | Min Cell Voltage | 3.46V | | ||
| - | | Max Cell Voltage | 3.50V | | ||
| - | |||
| - | ---- | ||
| ===== 12. Cell Identification in the GX Device ===== | ===== 12. Cell Identification in the GX Device ===== | ||