User Tools

Site Tools


battery_compatibility:hubble

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
battery_compatibility:hubble [2023-11-01 08:57] – [Parallel Limitations] warwickchapmanbattery_compatibility:hubble [2024-03-10 16:51] (current) – [Ve.Configure 3] warwickchapman
Line 100: Line 100:
     - CAN Mode => Victron     - CAN Mode => Victron
     - CAN Conn. To => Inverter     - CAN Conn. To => Inverter
-    - Serial Conn. To => Battery +    - Serial Conn. To => Battery (External CloudLink only) 
-  - Site Settings => Inverter Brand => Victron+    - RS232 Conn. To => Nothing (+ models with internal CloudLink only) 
 +    - Adaptive Cell Limits => Enable 
 +    - Save & Confirm 
 +  - Site Settings =>  
 +    - Inverter Brand => Victron 
 +    - (Optional) Add the IP address of the GX device - improves CloudLink display 
 +    - Save & Confirm 
 +    - Wait for Confirmation, scroll down and click Reboot for the settings to take effect
  
 Connect the Battery side of the type A cable into the CloudLink CAN port. Connect the Victron side of the type A cable to the CAN BMS port on the GX device (configured for 500kbps CAN BMS). The Hubble battery will display in the device list of the GX device. Connect the Battery side of the type A cable into the CloudLink CAN port. Connect the Victron side of the type A cable to the CAN BMS port on the GX device (configured for 500kbps CAN BMS). The Hubble battery will display in the device list of the GX device.
Line 165: Line 172:
     - Battery capacity: Use 100Ah per Hubble battery (excl. AM-10: 200Ah, AM-3: 50Ah, S-200: 200Ah, Blade: 137Ah). Eg. If there are 3 x AM-4, then capacity is 300Ah.     - Battery capacity: Use 100Ah per Hubble battery (excl. AM-10: 200Ah, AM-3: 50Ah, S-200: 200Ah, Blade: 137Ah). Eg. If there are 3 x AM-4, then capacity is 300Ah.
     - Sustain voltage, set the value from the tables below     - Sustain voltage, set the value from the tables below
-    - Dynamic cutoff, set the fallback value from the tables below+    - Dynamic cutoff, use the low cutoff value from the tables below
     - Restart offset, set the value from the tables below     - Restart offset, set the value from the tables below
  
battery_compatibility/hubble.1698825470.txt.gz · Last modified: 2023-11-01 08:57 by warwickchapman