Line 27: | Line 27: | ||
For assistance with installs that require more than 15 modules, please contact Hubble support. | For assistance with installs that require more than 15 modules, please contact Hubble support. | ||
+ | Note: The first batch of AM-10' | ||
+ | ==== Minimum Battery Sizing ==== | ||
+ | |||
+ | Hubble makes batteries available in two chemistries: | ||
+ | |||
+ | The benefit of the NMC batteries is they can deliver higher instantaneous power (their cells have a better C-rating) than the LFP batteries. | ||
+ | |||
+ | This gives the system designer choices. | ||
+ | |||
+ | Thus, the guidance we give to system designers on Battery: | ||
+ | ^ Chemistry ^ Guideline ^ | ||
+ | | NMC | Battery kWh : Inverter kVA should be at least 1:1 | | ||
+ | | LFP | Battery kWh : Inverter kVA should be > 1:1 | | ||
===== Required Firmware Versions ===== | ===== Required Firmware Versions ===== | ||
Line 87: | Line 100: | ||
- CAN Mode => Victron | - CAN Mode => Victron | ||
- CAN Conn. To => Inverter | - CAN Conn. To => Inverter | ||
- | - Serial Conn. To => Battery | + | - Serial Conn. To => Battery |
- | - Site Settings => Inverter Brand => Victron | + | - RS232 Conn. To => Nothing (+ models with internal CloudLink only) |
+ | - Adaptive Cell Limits => Enable | ||
+ | - Save & Confirm | ||
+ | - Site Settings => | ||
+ | - Inverter Brand => Victron | ||
+ | - (Optional) Add the IP address of the GX device - improves CloudLink display | ||
+ | - Save & Confirm | ||
+ | - Wait for Confirmation, | ||
Connect the Battery side of the type A cable into the CloudLink CAN port. Connect the Victron side of the type A cable to the CAN BMS port on the GX device (configured for 500kbps CAN BMS). The Hubble battery will display in the device list of the GX device. | Connect the Battery side of the type A cable into the CloudLink CAN port. Connect the Victron side of the type A cable to the CAN BMS port on the GX device (configured for 500kbps CAN BMS). The Hubble battery will display in the device list of the GX device. | ||
Line 116: | Line 136: | ||
Use VictronConnect to configure Victron MPPTs and the RS range of inverter/ | Use VictronConnect to configure Victron MPPTs and the RS range of inverter/ | ||
+ | |||
+ | ==== Multi RS ==== | ||
- Click the Settings icon top right | - Click the Settings icon top right | ||
Line 128: | Line 150: | ||
- Float voltage => Disabled or set this to the charge value from the tables below | - Float voltage => Disabled or set this to the charge value from the tables below | ||
- Storage voltage => Disabled or set this to the charge value from the tables below | - Storage voltage => Disabled or set this to the charge value from the tables below | ||
+ | |||
+ | ==== MPPT & MPPT RS ==== | ||
+ | |||
+ | - Click the Settings icon top right | ||
+ | - Click the Battery menu | ||
+ | - Battery preset => Select preset => Smart Lithium (LiFePO4) | ||
+ | - Absorption voltage => Set this to the charge value from the tables below | ||
+ | - Float voltage => Set this to the charge value from the tables below | ||
===== Ve.Configure 3 ===== | ===== Ve.Configure 3 ===== | ||
Line 142: | Line 172: | ||
- Battery capacity: Use 100Ah per Hubble battery (excl. AM-10: 200Ah, AM-3: 50Ah, S-200: 200Ah, Blade: 137Ah). Eg. If there are 3 x AM-4, then capacity is 300Ah. | - Battery capacity: Use 100Ah per Hubble battery (excl. AM-10: 200Ah, AM-3: 50Ah, S-200: 200Ah, Blade: 137Ah). Eg. If there are 3 x AM-4, then capacity is 300Ah. | ||
- Sustain voltage, set the value from the tables below | - Sustain voltage, set the value from the tables below | ||
- | - Dynamic cutoff, | + | - Dynamic cutoff, |
- Restart offset, set the value from the tables below | - Restart offset, set the value from the tables below | ||
battery_compatibility/hubble.1698767411.txt.gz · Last modified: 2023-10-31 16:50 by warwickchapman