battery_compatibility:discover
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| battery_compatibility:discover [2025-12-01 20:36] – dettingale | battery_compatibility:discover [2026-10-10 08:31] (current) – HELIOS ESS: model 52-48-16000; direct path uses the Victron VE.Can to CAN-bus BMS Type A cable with a terminator; patch-cable note for LYNK II only; section 5 numbering guy_stewart | ||
|---|---|---|---|
| Line 62: | Line 62: | ||
| * AES RACKMOUNT 48-48-5120 / 48-48-5120-H | * AES RACKMOUNT 48-48-5120 / 48-48-5120-H | ||
| - | * HELIOS ESS 42-48-16000 | + | * HELIOS ESS 52-48-16000 |
| **Victron Products** | **Victron Products** | ||
| Line 210: | Line 210: | ||
| 2. LYNK II Gateway | 2. LYNK II Gateway | ||
| - | The HELIOS ESS supports direct closed-loop communication with Victron | + | The HELIOS ESS supports direct closed-loop communication with a Victron |
| - | {{: | + | {{: |
| - | Use this cable for connections between | + | Use the [[battery_compatibility: |
| - | 1. Connect | + | 1. Plug the cable end labelled " |
| {{: | {{: | ||
| Line 231: | Line 231: | ||
| If communication is interrupted between the BMS and Victron inverter-charger, | If communication is interrupted between the BMS and Victron inverter-charger, | ||
| - | Skip to section 5. Configuring Victron Products. | + | For the DVCC settings in step 4, go to section 5.2.1 Configurable Closed-Loop Settings. The 250 kbit/s setting and the cable note in section 5.2 apply to the LYNK II path only. |
| ==== 4.2 Configuring the LYNK II ==== | ==== 4.2 Configuring the LYNK II ==== | ||
| Line 387: | Line 387: | ||
| - | ==== 5.1 Setting Up Closed-Loop Configuration ==== | + | ==== 5.2 Setting Up Closed-Loop Configuration |
| Refer to the latest Discover Energy Systems documentation for battery values and the latest Victron documentation for menu navigation and details on the setup procedure. | Refer to the latest Discover Energy Systems documentation for battery values and the latest Victron documentation for menu navigation and details on the setup procedure. | ||
| Line 410: | Line 410: | ||
| - | **NOTE:** If **Discover AES** does not appear on the Device List, confirm that the CAT5e or higher communication cable is a normal patch type, not a cross-over type. Use manufactured cables to avoid bad crimps and reduce the risk of a poor connection. | + | **NOTE: |
| - | === 5.1.1 Configurable Closed-Loop Settings === | + | === 5.2.1 Configurable Closed-Loop Settings === |
| During regular operation, the BMS sets the battery’s charge parameter limits, which the Victron GX device communicates to the inverter-charger and MPPT. | During regular operation, the BMS sets the battery’s charge parameter limits, which the Victron GX device communicates to the inverter-charger and MPPT. | ||
| Line 441: | Line 441: | ||
| - | === 5.1.2 Saving the Configurable Closed-Loop Settings === | + | === 5.2.2 Saving the Configurable Closed-Loop Settings === |
| **Device List > Settings > General > Reboot?** | **Device List > Settings > General > Reboot?** | ||
battery_compatibility/discover.1764621361.txt.gz · Last modified: by dettingale