battery_compatibility:can-bus_bms-cable
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
battery_compatibility:can-bus_bms-cable [2017-12-13 17:29] – created mvader | battery_compatibility:can-bus_bms-cable [2024-05-08 12:47] (current) – [1. Selecting the right cable] warwickchapman | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== VE.Can to CAN-bus BMS cables manual ====== | ====== VE.Can to CAN-bus BMS cables manual ====== | ||
- | ===== 1. Introduction ===== | + | Use these [[https:// |
- | Use this cable to connect a CAN-bus enabled battery to a Victron system. | + | |
- | The side labeled ' | ||
- | There are two types, each with different pinning. Some brands of batteries require a Type A. Other brands require | + | ===== 1. Selecting |
- | Batteries that require the Type A cable: | + | === ASS030710018 - VE.Can to CAN-bus BMS type A Cable 1.8m === |
* BYD B-Box | * BYD B-Box | ||
+ | * Pylontech US2000C/ | ||
- | Batteries that require the Type B cable: | + | === ASS030720018 - VE.Can to CAN-bus BMS type B Cable 1.8m === |
- | | + | * AXIstorage |
- | | + | |
* BMZ | * BMZ | ||
- | * Pylontech | + | |
+ | * Hubble Lithium | ||
+ | * LG Chem Resu | ||
+ | | ||
+ | * Solar MD BMS EX | ||
+ | * Freedom Won eTower | ||
- | ===== 2. Pin-out ===== | + | === ASS030064950 RJ45 UTP Cable (Standard Ethernet) |
+ | * Bluenova Energy Storage | ||
+ | * Cegasa eBick | ||
+ | * Freedom Won LiTE | ||
+ | * MG Energy Systems | ||
- | For the do-it-yourselvers: | + | === Custom (See Battery Documentation) === |
+ | * Exide | ||
+ | * SolarMD Logger V2 | ||
- | ==== 2.1 Type A ==== | + | ===== 2. Installation ===== |
+ | |||
+ | The side labeled ' | ||
+ | |||
+ | Both port types (VE.Can and BMS-Can) on a GX Device can be configured for use with a CAN-bus BMS connected third party battery. | ||
+ | |||
+ | For configuration, | ||
+ | |||
+ | ===== 3. Pin-out ===== | ||
+ | |||
+ | In some cases it might be needed to make the cable at the location. Find below the pin-outs. Make sure to very carefully test the cable after crimping it. Self-made cables are very often the causes of very hard to diagnose problems. | ||
+ | |||
+ | ==== 3.1 Type A ==== | ||
^ Function ^ Victron VE.Can side ^ Battery side ^ | ^ Function ^ Victron VE.Can side ^ Battery side ^ | ||
| GND | Pin 3 | Pin 6 | | | GND | Pin 3 | Pin 6 | | ||
Line 29: | Line 50: | ||
| CAN-H | | CAN-H | ||
- | ==== 2.2 Type B ==== | + | ==== 3.2 Type B ==== |
^ Function ^ Victron VE.Can side ^ Battery side ^ | ^ Function ^ Victron VE.Can side ^ Battery side ^ | ||
Line 36: | Line 57: | ||
| CAN-H | | CAN-H | ||
- | ===== DISQUS ===== | + | |
- | ~~DISQUS~~ | + |
battery_compatibility/can-bus_bms-cable.1513182574.txt.gz · Last modified: 2017-12-13 17:29 by mvader