- | ====== Victron & Aquion AHI ===== | + | ====== Victron & GREENROCK |
- | + | ||
- | **Note: this is a draft!** | + | |
===== Compatible Victron products ===== | ===== Compatible Victron products ===== | ||
All 48V Multis and Quattros. Also all MPPT Solar chargers that can work with a 48V battery. | All 48V Multis and Quattros. Also all MPPT Solar chargers that can work with a 48V battery. | ||
- | Note that there is no integration in the Color Control GX required nor available: it will not (yet) read data directly from the Aquion AHI BMS. | + | Note that there is no integration in the Color Control GX required nor available: it will not (yet) read data directly from the GREENROCK |
===== Configuration ===== | ===== Configuration ===== | ||
- | ^ Parameter | + | ^ Parameter |
- | | Charge curve | Fixed | | + | | Charge curve | Fixed |
- | | Absorption voltage | + | | Absorption voltage |
- | | Float voltage | + | | Float voltage |
- | | Storage | + | | Storage |
- | | Charge current | + | | Charge current |
- | | Repeated absorption time | 4 hrs | | + | | Repeated absorption time | 4 hrs |
- | | Repeated absorption interval | Not required | | + | | Repeated absorption interval |
- | | Max absorption time | 4 hrs | | + | | Max absorption time |
- | | Low voltage disconnect | + | | Low voltage disconnect |
Notes: | Notes: | ||
- Under normal conditions, all the energy should be discharged when you reach 40V. However, during short high current discharges, the battery voltage can momentarily drop below 40V. Therefore set the low voltage disconnect as low as possible. | - Under normal conditions, all the energy should be discharged when you reach 40V. However, during short high current discharges, the battery voltage can momentarily drop below 40V. Therefore set the low voltage disconnect as low as possible. | ||
+ | |||
+ | ===== ESS ===== | ||
+ | |||
+ | Make sure to lower the Dynamic Cut-off parameters, to 37.5, 37.4, 37.3 and 37.2. | ||