User Tools

Site Tools


auto-generator-start-stop:start

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
auto-generator-start-stop:start [2018-12-09 07:23] – [Starting a genset with three-wire interface] mvaderauto-generator-start-stop:start [2019-01-22 10:16] – external edit 127.0.0.1
Line 3: Line 3:
 Various Victron products have functions to automatically signal when to start and stop a generator. Here is advice on when to use which product and method. Various Victron products have functions to automatically signal when to start and stop a generator. Here is advice on when to use which product and method.
  
-When there is a [[venus-os:start|Venus-device]] (CCGX, Venus GX, or other) in the system, the best option is to use that [[ccgx:generator_start_stop|Generator Start Stop mechanism]]. Its the most feature-rich generator start/stop system that we have to offer. It provides for basic functions as starting and stopping on Battery State of Charge, Battery voltage as well as High load situations. And also has many advanced features, including automatic test runs and silent times.+When there is a [[venus-os:start|Venus-device]] (CCGX, Venus GX, or other) in the system, the best option is to use its [[ccgx:generator_start_stop|Generator Start Stop mechanism]]. Its the most feature-rich generator start/stop system that we have to offer. It provides for basic functions as starting and stopping on Battery State of Charge, Battery voltage as well as High load situations. And also has many advanced features, including automatic test runs and silent times.
  
 The next most used option is a BMV-700 Battery Monitor or similar model. It can start the generator on low battery voltage and/or low battery state of charge. See the [[https://www.victronenergy.com/battery-monitors/bmv-700#manual|BMV-700 manual]] for configuration. The next most used option is a BMV-700 Battery Monitor or similar model. It can start the generator on low battery voltage and/or low battery state of charge. See the [[https://www.victronenergy.com/battery-monitors/bmv-700#manual|BMV-700 manual]] for configuration.
Line 39: Line 39:
  
 i have some systeme using this solution and all looks ok i have some systeme using this solution and all looks ok
 +
  
 ===== DISQUS ===== ===== DISQUS =====
 ~~DISQUS~~ ~~DISQUS~~
 +
auto-generator-start-stop/start.txt · Last modified: 2021-02-25 13:46 by marmour

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki