actor_offgrid [2019-05-24 13:12] – created lucianactor_offgrid [2023-10-25 15:36] (current) bob
Line 1: Line 1:
-====== MyPv Ac-Thor and Victron Energy Off-Grid ======+====== my-PV AC-Thor and Victron Energy Off-Grid ====== 
 + 
 +For an Off-Grid system. when the batteries are full and we still have AC coupled PV power available, that power is lost. We could use that power and send it to a boiler or something similar. For this we are using a device from my-PV called AC-Thor. 
 + 
 +The schematic for this kind of system looks like this (the meter from my-PV is not needed in this setup):  
 + 
 +{{::offgrid_-_acthor_integration_for_lucian.png?nolink|}} 
 + 
 +First setup:  
 + 
 +AC-Thor device must be connected on the AC output of the Multi/Quattro just like the AC coupled PV inverter.  
 + 
 + 
 +Using the device touch screen, select Information menu and go to the third screen to find the current IP address. 
 +  
 +{{:ac_thor_ip_address.jpg?nolink|}} 
 + 
 +Open a browser, put that IP address into the address field and press enter  
 + 
 +The webpage should look like this:  
 + 
 +{{::ac_thor_main_page.jpg?nolink|}} 
 + 
 +Please check the firmware version on AC-Thor device, must be at least a0010006.  
 +Go to setting and select the “Mode”. For ESS select ”Hot water 3KW”, for off-grid systems, select  “Frequency-Mode”.  
 + 
 +{{::ac_thor_frequency.jpg?nolink&800|}} 
 + 
 +Go to Frequency-Modus and define Frequency start value 50.1Hz and the Frequency end value 51Hz. 
 + 
 +{{::ac_thor_frequency_values.jpg?nolink&800|}} 
 + 
 +On the Multiplus or Quattro, using Ve.config, add the PV Inverter support Assistant. 
 + 
 +-> The correct working of the frequency shift in the PV Inverter assistant needs to physically have a PV inverter installed on ACout which can feed into the Victron system.  
  
-For an Off-Grid system. when the batteries are full and we still have PV power available, that power is lost. We could use that power and send it to a boiler or something similar. For this we are using a device from My PV called AC-Thor. 
  
-The schematic for this kind of system looks like this:  