- | When the batteries are full, we still have PV power available, but our grid operator doesn' | + | When the batteries are full, we still have PV power available, but our grid operator doesn' |
Line 17: | Line 17: | ||
Must be in the same LAN network as Color GX or Venus GX, with DHCP enable (default). | Must be in the same LAN network as Color GX or Venus GX, with DHCP enable (default). | ||
- | Using the device touch screen, select Information menu and go to the third screen to find the current IP address. | + | Using the device touch screen, select Information menu and go to the third screen to find the current IP address. |
+ | |||
+ | {{: | ||
+ | |||
+ | Open a browser, put that IP address into the address field and press enter | ||
+ | |||
+ | The webpage should look like this: | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | Please check the firmware version on AC-Thor device, must be at least a0010006. | ||
+ | Go to setting and select the “Mode”. For ESS select ”Hot water 3KW”, . | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | In order to have communication between the Color/Venus GX device and Ac-Thor, some parameters must be configured: | ||
+ | |||
+ | |||
+ | |||
+ | On Signal Source, select “Adjustable Modbus TCP(Sunspec etc)”. | ||
+ | |||
+ | Device ID must be 0. | ||
+ | |||
+ | Metter Register 820, Int16 and -feed in. | ||
+ | |||
+ | For Scale Register, don’t select anything. | ||
+ | |||
+ | For Modbus Port, leave the default value (502). | ||
+ | |||
+ | On the IP address field, you have to put the VenusGX/ | ||
+ | |||
+ | On the Control target, recommended value is -50W. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Press Save to store the parameters. | ||
+ | |||
+ | On the Venus/Color GX please be sure that Modbus TCP is enabled (Setting, Services, Modbus/TCP) | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Also in Setting /ESS, Feed-in excess solar power must me enabled for system with PV panels connected using MPPT’s | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | If everything is correctly configured, you should see in the information screen of the Ac-Thor, the grid consumption/ | ||
+ | |||
+ | {{:: | ||
+ | {{:: | ||
+ | |||
+ | AC-Thor will control the energy sent to the boiler so that the energy sent to the grid is approximately 50W. | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | To prevent boiler to over heat, please be sure the temperature sensor is connected to AC-Thor and installed inside the boiler. The temperature parameters can be configured in the settings menu: | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | **AC-THOR Technical specifications: | ||
+ | |||
+ | * mains voltage 230 V, 50 Hz | ||
+ | |||
+ | * outputs 0-3000 W infinitely variable + switching output 16 A | ||
+ | |||
+ | * mains connection Single-phase, | ||
+ | |||
+ | * consumer connection Protective contact socket for resistive loads | ||
+ | |||
+ | * display Color Graphics, Touch Screen 2.83 " | ||
+ | |||
+ | * connection cable 2,8 m | ||
+ | |||
+ | * dimensions (W x H x D) 135 x 210 x 65 mm |