Line 24: Line 24:
   * Systems with only a grid-tied PV inverter will fail when there is a grid black-out. A micro-grid system will continue to operate, and even keep using solar power.   * Systems with only a grid-tied PV inverter will fail when there is a grid black-out. A micro-grid system will continue to operate, and even keep using solar power.
   * It is also possible to run a AC-coupled micro-grid on a generator   * It is also possible to run a AC-coupled micro-grid on a generator
-  * Most brands of PV inverters can be used for these systems, they need to be setup to support frequency shifting, often called the island-mode or micro-grid mode. For SolarEdge settings, see [[venus-os:gx_solaredge|]]. For Fronius settings, see [[ac_coupling:fronius|AC-coupled PV with Fronius PV Inverters]].+  * Most brands of PV inverters can be used for these systems, they need to be setup to support frequency shifting, often called the island-mode or micro-grid mode. For SolarEdge settings, see [[venus-os:gx_solaredge|]], for Fronius settings, see [[ac_coupling:fronius|AC-coupled PV with Fronius PV Inverters]] & for reading and controling ABB/Fimer inverters, see [[ccgx:abb_fimer|AC-coupled PV with ABB/Fimer PV Inverters]]. 
 +  * To read out SMA inverters, see [[ccgx:ccgx_sma|AC-coupled PV with SMA PV Inverters]].
   * If power will be fed back into the grid an anti-islanding device may have to be added to the system, depending on local regulations.    * If power will be fed back into the grid an anti-islanding device may have to be added to the system, depending on local regulations. 
  
Line 96: Line 97:
 ===== 5 Software configuration ===== ===== 5 Software configuration =====
  
-Multis and Quattros with factory settings will not shift the AC output frequency to regulate charge current. When setting up an AC Coupled system, install either the [[ess:start|ESS Assistant]] (for grid-connected systems) or the [[:assistants:pv-inverter-support]] (for off-grid systems).+Multis and Quattros with factory settings will not shift the AC output frequency to regulate charge current. When setting up an AC Coupled system, install either the [[ess:start|ESS Assistant]] (for grid-connected systems) or the [[:assistants:pv-inverter-support]] (for off-grid systems).  
 + 
 +The Inverter RS will automatically shift frequency without any additional configuration required when a surplus/back-feed of AC is detected on the AC-output.
  
 Other options, __all deprecated__, are: Other options, __all deprecated__, are:
Line 105: Line 108:
 ===== Monitoring ===== ===== Monitoring =====
  
-See [[ccgx:start|section 1.5 in the GX manual]].+See [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html#UUID-347e92f6-0d4b-eef5-9787-22fbcb9aa13c|Connecing a PV inverter section of the GX manual]].
  