ac_coupling:start [2020-03-01 13:36] – [1.1 What is AC-coupling?] roi.oac_coupling:start [2020-05-29 16:54] – [2.1 Rule definition] guy_stewart
Line 38: Line 38:
 **The max PV power must be equal or less than the VA rating of the inverter/charger** **The max PV power must be equal or less than the VA rating of the inverter/charger**
 ==== 2.1 Rule definition ==== ==== 2.1 Rule definition ====
-In both grid-connected and off-grid systems with PV inverters installed on the output of a Multi, Inverter or Quattro, there is a maximum of PV power that can be installed. This limit is called the __factor 1.0 rule__: 3.000 VA Multi = 3.000 Wp installed solar power. So for a 8.000 VA Quattro the maximum is 8.000 Wp, for two paralleled 8000 VA Quattros the maximum is 16.000 Wp, etc.+In both grid-connected and off-grid systems with PV inverters installed on the output of a Multi, Inverter or Quattro, there is a maximum of PV power that can be installed. This limit is called the __factor 1.0 rule__: 3.000 VA Multi >= 3.000 Wp installed solar power. So for a 8.000 VA Quattro the maximum is 8.000 Wp, for two paralleled 8000 VA Quattros the maximum is 16.000 Wp, etc.
  
 ==== 2.2 Example and background ==== ==== 2.2 Example and background ====