Line 16: Line 16:
   * For on-grid / energy-storage systems, load the Multi or Quattro with the ESS Assistant. Read information about ESS in the [[ess:design-installation-manual|]].   * For on-grid / energy-storage systems, load the Multi or Quattro with the ESS Assistant. Read information about ESS in the [[ess:design-installation-manual|]].
  
-And the [[ac_coupling:start|1:1 rule]] must be adhered to.+And the [[ac_coupling:start|1:limit rule]] must be adhered to.
  
 ===== Fronius / Victron specifics ===== ===== Fronius / Victron specifics =====
Line 77: Line 77:
 ===== Zero Feed-in ===== ===== Zero Feed-in =====
  
-It is possible to make a Zero feed-in system with Victron & Fronius. The Venus device will the control the Fronius output power. See the [[ess:design-installation-manual|ESS manual]], chapter 2.1.3 Fronius Zero feed-in for details.+It is possible to make a Zero feed-in system with Victron & Fronius. The Venus device will the control the Fronius output power. See the [[ess:design-installation-manual|ESS manual]], chapter 4.3.11 Fronius Zero feed-in for details.
 ===== Frequently Asked Questions ===== ===== Frequently Asked Questions =====
  
Line 91: Line 91:
 ==== Q4 Can I use the Fronius Smart Meter? ==== ==== Q4 Can I use the Fronius Smart Meter? ====
  
-No, when using a Fronius PV Inverter in a Victron system it is not possible to use the Fronius Smart Meter.+That depends on the type of system and software configuration. 
 + 
 +Fronius Smart Meter can be used in these two situations: 
 + 
 +  - when used only for reporting to Solarweb 
 +  - when used for limiting export, in a system where the Victron system is not configured as an ESS system. 
 + 
 +The Fronius Smart-Meter can not be used for the Fronius built-in export limiting feature when part of a Victron ESS system. Instead, use the Victron ESS Fronius Zero-feed in feature, see chapter 4.3.11, Fronius Zero Feed-in, in the [[ess:design-installation-manual|ESS manual]].
  
-Use any of the [[energy-meters:start|Victron supplied Energy Meters]] instead. 
  
 ==== Q5 How can I get the Fronius firmware that improves flickering? ==== ==== Q5 How can I get the Fronius firmware that improves flickering? ====