ac_coupling:fronius
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
ac_coupling:fronius [2016-12-15 13:11] – [Frequency shifting] mvader | ac_coupling:fronius [2019-07-01 13:24] – [Zero Feed-in] mvader | ||
---|---|---|---|
Line 16: | Line 16: | ||
* For on-grid / energy-storage systems, load the Multi or Quattro with the ESS Assistant. Read information about ESS in the [[ess: | * For on-grid / energy-storage systems, load the Multi or Quattro with the ESS Assistant. Read information about ESS in the [[ess: | ||
- | And the [[ac_coupling: | + | And the [[ac_coupling: |
===== Fronius / Victron specifics ===== | ===== Fronius / Victron specifics ===== | ||
Line 23: | Line 23: | ||
Compatible inverters are: | Compatible inverters are: | ||
- | * Fronius | + | * Fronius |
- | * Fronius | + | * Fronius |
- | * Fronius | + | * Fronius |
* Fronius Agilo (3~, 75 kW up to 100 kW) -> Software // | * Fronius Agilo (3~, 75 kW up to 100 kW) -> Software // | ||
* Fronius IG Plus V (1~, 2~, 3~, 2.5 kW up to 12 kW) -> from //IGF 5.0.66// on with settings according to the Victron recommendations | * Fronius IG Plus V (1~, 2~, 3~, 2.5 kW up to 12 kW) -> from //IGF 5.0.66// on with settings according to the Victron recommendations | ||
Line 57: | Line 57: | ||
Table for settings for 50Hz and 60Hz frequency | Table for settings for 50Hz and 60Hz frequency | ||
| ** State ** | ** 50Hz ** | ** 60Hz ** |. | | | ** State ** | ** 50Hz ** | ** 60Hz ** |. | | ||
- | | Start| | + | | Start| |
| Minimum| 52.7 | 62.7|Hz| | | Minimum| 52.7 | 62.7|Hz| | ||
| Disconnect| 53.0 | 63.0|Hz| \\ | | Disconnect| 53.0 | 63.0|Hz| \\ | ||
Line 75: | Line 75: | ||
A video instruction how to set up the Datamanager 2.0 + Solar.web can be found [[https:// | A video instruction how to set up the Datamanager 2.0 + Solar.web can be found [[https:// | ||
- | ===== Frequently asked questions | + | ===== Zero Feed-in |
- | === Why doesn' | + | It is possible to make a Zero feed-in system with Victron & Fronius. The Venus device will the control the Fronius output power. See the [[ess: |
+ | ===== Frequently Asked Questions ===== | ||
+ | |||
+ | ==== Q1 Why doesn' | ||
The first two frequencies do not need to be the same since the Multi actively regulates. | The first two frequencies do not need to be the same since the Multi actively regulates. | ||
- | === I have an Fronius IG inverter (not Plus), can that work? === | + | ==== Q2 I have an Fronius IG inverter (not Plus), can that work? ==== |
No, the IG inverters cannot be made to work in a MicroGrid system. The appropriate substitute for an IG 30 is the GALVO 2.5-1 or an IG Plus 25V-1 (depending on the desired DC voltage range). | No, the IG inverters cannot be made to work in a MicroGrid system. The appropriate substitute for an IG 30 is the GALVO 2.5-1 or an IG Plus 25V-1 (depending on the desired DC voltage range). | ||
+ | ==== Q3 The system is locked to 53 Hz and does not resume ==== | ||
+ | See [[: | ||
+ | ==== Q4 Can I use the Fronius Smart Meter? ==== | ||
+ | |||
+ | That depends on the type of system and software configuration. | ||
+ | |||
+ | A Fronius Smart Meter can be used in these two situations: | ||
+ | |||
+ | - when used only for reporting to Solarweb | ||
+ | - when used for limiting export, in a system where the Victron system is not configured as an ESS system. | ||
+ | |||
+ | The Fronius Smart-Meter can not be used for the Fronius built-in export limiting feature when part of a Victron ESS system. Instead, use the Victron ESS Fronius Zero-feed in feature, see chapter 4.3.11, Fronius Zero Feed-in, in the [[ess: | ||
+ | |||
+ | |||
+ | ==== Q5 How can I get the Fronius firmware that improves flickering? ==== | ||
+ | |||
+ | Fronius has a special firmware available, on request, that fixes light flickering issues that occur on certain installations under certain circumstances. | ||
+ | |||
+ | For Fronius PV inverters produced after 2018-week 16, contain the flicker-fix already straight from production. | ||
+ | |||
+ | To update earlier and/or already installed PV Inverters, contact Fronius Tech Support for the file. The required file is fro29130.upd. Which works for all snap-inverter models (Primo, Symo and Eco). There is no, and will be no, fix available for Fronius Galvos. | ||
+ | |||
+ | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ | ||
+ | |||
+ |
ac_coupling/fronius.txt · Last modified: 2023-11-30 07:13 by guy_stewart