====== Pytes HV batteries ====== ===== Manufacturer links ===== * Homepage: [[https://www.pytesess.com/|Pytes ESS]] * Product page: [[https://www.pytesess.com/High-Voltage-Battery/HV48100.html|HV48100]] * Datasheet: not publicly linked; see the [[https://www.pytesess.com/Catalogue/|Pytes download centre]] This page covers HV48100 and HV48300 Max. Pytes also offers HV48100 SE and HV48300 Max SE. The calculations below do not apply to the SE models. ===== Use with the HS19 (650 - 1000 V DC) ===== These calculations check voltage limits only. They do not establish compatibility. They keep the full stated battery voltage range within the HS19 and battery controller limits. **HV48100** * Modules per stack: **14 or 15** are within the product range. * Voltage range: **665 - 870 V DC** * Nominal Capacity per stack: **71.68 - 76.8 kWh**. **HV48300 Max** * Modules per stack: **15 - 17**. * Voltage range across these configurations: **672 - 979.2 V DC**. * Capacity per stack: **241.14 - 273.29 kWh**. * A stack with 14 modules can fall to 627.2 V. A stack with 18 modules can reach 1036.8 V. Each stack has its own voltage range. The combined range above is not the range of each stack. ===== Product specifications ===== **HV48100** * Battery module (BMU): 51.2 V nominal, 5.12 kWh, 45.5 - 58 V. * Battery controller (BCU): 200 - 870 V working range; 5 - 15 BMUs. **HV48300 Max** * Battery module (BMU): 51.2 V nominal, 16.076 kWh, 44.8 - 57.6 V. * Battery controller (BCU): 224 - 1497 V working range; 5 - 26 BMUs. ===== Setup guide ===== Contact battery manufacturer for setup instructions.