[{"id":230,"name":"Lynx Shunt VE.Can","short_name":"Lynx Shunt VE.Can","category":"Battery monitors","description":"<p>The Lynx Shunt VE.Can is an intelligent 1000A shunt with location for a fuse (not included), the built-in battery monitor accurately monitors the state of charge of your battery. Use a GX device (e.g. Cerbo GX) for reading out the information. Part of the modular Lynx distribution system.<\/p>","modified_at":"2025-09-15 13:46:23","image":"https:\/\/www.victronenergy.com\/upload\/products\/230_588_20180706090107.png","sku_information":[{"sku":"LYN040102100","created_at":"2012-05-02 21:38:05","html_description":null,"is_eol":true}],"documents":[{"id":1534,"sku":["LYN040102100","LYN040102110"],"name":"Oceanvolt teams up with Victron Energy","document_type":"Press release","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Press_release-_20131121_Oceanvolt-teams-up-with-Victron-Energy_EN.pdf","notes":""},{"id":1386,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can","document_type":"Enclosure dimension","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Shunt-VE.Can.pdf","notes":""},{"id":1736,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (stp)","document_type":"Enclosure dimension","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Shunt-VE.Can-3D.STEP","notes":""},{"id":1399,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (3D)","document_type":"Enclosure dimension","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Shunt-VE.Can-3D.pdf","notes":""},{"id":7791,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can","document_type":"Datasheet","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-Lynx-Shunt-VE.Can-EN-.pdf","notes":""},{"id":2083,"sku":["LYN040102100","LYN040102110"],"name":"Modbus-TCP register list","document_type":"Technical information","url":"https:\/\/www.victronenergy.com\/upload\/documents\/CCGX-Modbus-TCP-register-list-3.81.xlsx","notes":""},{"id":3853,"sku":["LYN040102100","LYN040102110"],"name":"Marine Integration Guide","document_type":"Technical information","url":"https:\/\/www.victronenergy.com\/live\/ve.can:nmea-2000:start","notes":""},{"id":4570,"sku":["LYN040102100","LYN040102110"],"name":"Declaration of Conformity - Lynx DC distribution","document_type":"Certificate","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-DC-distribution-2023-08-28.pdf","notes":""},{"id":11694,"sku":["LYN040102100","LYN040102110"],"name":"Brand video","document_type":"Promo video","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Promo videos\/Ad videos\/Brand video\/16x9\/EN_Brand video.mp4","notes":""},{"id":1184,"sku":["LYN040102100","LYN040102110"],"name":"Data communication with Victron Energy products","document_type":"Technical information","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Technical-Information-Data-communication-with-Victron-Energy-products_EN.pdf","notes":""},{"id":3691,"sku":["LYN040102100","LYN040102110"],"name":"ISO9001 certificate","document_type":"Certificate","url":"https:\/\/www.victronenergy.com\/upload\/documents\/ISO9001-certificate-2024-EN.pdf","notes":""},{"id":129,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt (top)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx_Shunt_1000A_top_LYN040102000.jpg","notes":""},{"id":127,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt (left)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx_Shunt_1000A_left_LYN040102000.jpg","notes":""},{"id":131,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt (right)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx_Shunt_1000A_right_LYN040102000.jpg","notes":""},{"id":612,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (top open)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx shunt VE.Can (top-open).png","notes":""},{"id":613,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (top open1)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx shunt VE.Can (top_open1).png","notes":""},{"id":614,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (front open)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx shunt VE.Can (front_open).png","notes":""},{"id":615,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (left open)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx shunt VE.Can (left_open).png","notes":""},{"id":732,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (top open with fuse)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx shunt VE.Can (top_open with fuse).png","notes":""},{"id":735,"sku":["LYN040102100","LYN040102110"],"name":"Lynx Shunt VE.Can (inside with fuse2)","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx Shunt VE.Can (inside with fuse2).png","notes":""}],"external_images":[{"id":4193,"sku":["LYN040102100"],"name":"aws_script_sku_LYN040102100","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/aws_script_sku_LYN040102100.jpg","notes":""},{"id":4606,"sku":["LYN040102100"],"name":"main image for LYN040102100","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/B00NT9X18M.MAIN.LYN040102100.jpg","notes":""}],"main_images":[{"id":4606,"sku":["LYN040102100"],"name":"main image for LYN040102100","document_type":"High quality photo","url":"https:\/\/www.victronenergy.com\/upload\/documents\/B00NT9X18M.MAIN.LYN040102100.jpg","notes":""}],"sku":["LYN040102100","LYN040102110"],"qr_images":{"png":{"black_on_white":"https:\/\/www.victronenergy.com\/qr-image\/3i.png?foreground=000000&background=ffffff","white_on_black":"https:\/\/www.victronenergy.com\/qr-image\/3i.png?foreground=ffffff&background=000000","white_on_blue":"https:\/\/www.victronenergy.com\/qr-image\/3i.png?foreground=ffffff&background=4790d0","white_on_transparent":"https:\/\/www.victronenergy.com\/qr-image\/3i.png?foreground=ffffff&transparent=true"},"svg":{"black_on_white":"https:\/\/www.victronenergy.com\/qr-image\/3i.svg?foreground=000000&background=ffffff","white_on_black":"https:\/\/www.victronenergy.com\/qr-image\/3i.svg?foreground=ffffff&background=000000","white_on_blue":"https:\/\/www.victronenergy.com\/qr-image\/3i.svg?foreground=ffffff&background=4790d0","white_on_transparent":"https:\/\/www.victronenergy.com\/qr-image\/3i.svg?foreground=ffffff&transparent=true"}},"pms_technical_data":[{"sku":"LYN040102100","field_name":"busbarConnections","field_value":"M8"},{"sku":"LYN040102100","field_name":"busbarDimensions","field_value":"8mm x 30mm"},{"sku":"LYN040102100","field_name":"busbarMaterial","field_value":"Tinned copper"},{"sku":"LYN040102100","field_name":"colour","field_value":"Blue (RAL 5012)"},{"sku":"LYN040102100","field_name":"currentRating","field_value":"1,000 A"},{"sku":"LYN040102100","field_name":"dataConnection","field_value":""},{"sku":"LYN040102100","field_name":"depth","field_value":"80 mm"},{"sku":"LYN040102100","field_name":"fuseConnections","field_value":"M8"},{"sku":"LYN040102100","field_name":"fuseDummy","field_value":"Not included"},{"sku":"LYN040102100","field_name":"height","field_value":"190 mm"},{"sku":"LYN040102100","field_name":"material","field_value":"ABS"},{"sku":"LYN040102100","field_name":"maxHumidity","field_value":"95 %"},{"sku":"LYN040102100","field_name":"operatingTempRange","field_value":"[-40, 60] \u00b0C"},{"sku":"LYN040102100","field_name":"powerConnectionDistributor","field_value":"RJ10 (RJ10 cables ship with each Lynx Distributor)"},{"sku":"LYN040102100","field_name":"powerConsumption","field_value":"60mA (12V) \/  33mA (24V) \/ 20mA (48V)"},{"sku":"LYN040102100","field_name":"programmableRelay","field_value":"Potential free alarm contact: 3A at 30VDC or 250VAC"},{"sku":"LYN040102100","field_name":"protectionCategory","field_value":"IP22"},{"sku":"LYN040102100","field_name":"relayConnection","field_value":"Screw terminals"},{"sku":"LYN040102100","field_name":"reversePolarityProtection","field_value":"No"},{"sku":"LYN040102100","field_name":"storageTempRange","field_value":"[-40, 60] \u00b0C"},{"sku":"LYN040102100","field_name":"systemVoltages","field_value":"12V or 24V or 48V"},{"sku":"LYN040102100","field_name":"temperatureSensorConnection","field_value":"Screw terminals"},{"sku":"LYN040102100","field_name":"veCan","field_value":"RJ45 (Two RJ45 terminators included)"},{"sku":"LYN040102100","field_name":"voltageRange","field_value":"[9, 70] V"},{"sku":"LYN040102100","field_name":"weight","field_value":"1.4 kg"},{"sku":"LYN040102100","field_name":"width","field_value":"180 mm"}]}]